Pre-integrated outdoor cabinets for peak shaving and demand charge management. Liquid cooling on the larger frames keeps cell temperature spread under 3 °C, which is what actually determines whether the warranty holds at scale.
Pre-integrated outdoor cabinets for peak shaving and demand charge management. Liquid cooling on the larger frames keeps cell temperature spread under 3 °C, which is what actually determines whether the warranty holds at scale.
Bench-tested combinations. Closed loop means the inverter reads state of charge, current limits and alarms directly from the BMS.
| Inverter | Model tested | SC-R Series | SC-W Series | SC-HV Series | Last verified |
|---|---|---|---|---|---|
| Deye | SUN-12K-SG04LP3 | Closed loop | Closed loop | Closed loop | Jul 2026 |
| Deye | SUN-5K-SG03LP1 | Closed loop | Closed loop | Not tested | Jun 2026 |
| Fronius | Symo GEN24 10.0 Plus | Not tested | Not tested | Closed loop | Feb 2026 |
| Goodwe | ET 10K-BH | Not tested | Not tested | Closed loop | Mar 2026 |
| Growatt | SPF 5000 ES | Closed loop | Voltage mode | Not applicable | May 2026 |
| Growatt | SPH 10000TL3 BH | Closed loop | Closed loop | Not tested | Jun 2026 |
| Luxpower | SNA 5000 WPV | Closed loop | Closed loop | Not tested | Jun 2026 |
| Must | PV18-5248 VHM | Closed loop | Voltage mode | Not applicable | Jan 2026 |
| SMA | Sunny Island 6.0H | Closed loop | Voltage mode | Not applicable | Apr 2026 |
| SMA | Sunny Tripower Smart Energy | Not tested | Not tested | Closed loop | Apr 2026 |
| Sofar | HYD 10KTL-3PH | Closed loop | Closed loop | Not tested | Mar 2026 |
| Sol-Ark | 15K-2P-N | Closed loop | Voltage mode | Not tested | May 2026 |
| Victron | MultiPlus-II 48/5000 | Closed loop | Closed loop | Not applicable | Jul 2026 |
| Victron | Quattro 48/10000 | Closed loop | Closed loop | Not applicable | Jul 2026 |
Your inverter not listed? Request a compatibility test
| Document | Applies to | Revision | Updated | Languages | Size |
|---|---|---|---|---|---|
| C&I storage brochure | SC-C | 2026 ed. | Jun 2026 | English | 11.7 MB |
| CAN protocol, Deye | SC-R, SC-W, SC-HV | v2.4 | Jul 2026 | English | 0.3 MB |
| CAN protocol, Growatt | SC-R, SC-W | v2.1 | Jun 2026 | English | 0.3 MB |
| CAN protocol, Victron | SC-R, SC-W | v2.2 | Jul 2026 | English | 0.3 MB |
| CE declaration of conformity | All systems | — | Jan 2026 | English | 0.7 MB |
| Cycle life report, 6000 cycles | SC-R51100 | — | Jan 2026 | English | 3.2 MB |
| Firmware update tool, Windows | All systems | v1.4 | Jun 2026 | English | 12.4 MB |
| Full range brochure 2026 | All | 2026 ed. | Jun 2026 | English, German, Spanish | 18.2 MB |
| IEC 62619 certificate | All systems | — | Mar 2026 | English | 1.8 MB |
| OEM capability brochure | All | 2026 ed. | May 2026 | English | 6.3 MB |
| Residential storage brochure | SC-R, SC-W, SC-AIO | 2026 ed. | Jun 2026 | English, Spanish | 9.4 MB |
| RS485 Modbus register map | All systems | v3.0 | Jun 2026 | English | 0.5 MB |
Send the quantity, destination market and the inverter you pair it with. An engineer replies with a real configuration and a real price.